What is the step-by-step process of iso 21702?

broken image

The iso 21702 is a test that helps detect antiviral activities on the plastic surface. It also works as the go-to testing method in virology. To check the antibacterial workings in the testing surface, the tester uses the method and detects viruses. 

The cytotoxicity control

The ISO21702 test takes help from the cultured host cells. As a result, it helps detect the cultured host cells. The amount of the infectious virus that is being recovered from the end of the test surface can also be done with the help of this testing process. The tester will now add these recovered cells can also be added to the host cells so that the virus will be able to destroy the boat cells or not. This is the entire process to detect if the testing is helpful to detect the actual results with the help of this test. 

The back titration 

Back titration is also a complete process that can help the test get effective results in every situation. In this process, the detection of the viruses that are being retrieved can also be checked. As a result, it is also denoted as the quickest method that helps to detect if the viruses are getting back to the test surface or not. 

VRS controls 

The VRS control is a process that also helps detect the virus that is taking place in the whole testing process. This control process also helps to detect that the antiviral tests are being done correctly on a surface. The VRS consists of two controls that are the positive control as well as one negative control. These are generally being used by the tester so that they will be able to test material and the reference materials properly. Where in the positive control, the tester will be able to test the antiviral properties. In the negative portion, they have to insert plastic products and ensure that none of the antiviral properties is present. In this process, it will be checked to see if the virus inactivations are taking place in the test or not. 

Conclusion 

Here is the process that can help the tester to perform the testing of the iso 21702. So, the lab operator should ensure that they will perform the same process without any hassle. So, this is another process where you will get the foremost results from the testing process that a tester would check in any situation. Here is the complete process. Hopefully, it will generate effective results for the testing process. This is a testing process that will also generate effective testing results. So, these are the steps that a tester can check effectively in any situation. It will be helpful for the pathologist also.